Dust detector adopts high temperature and high pressure resistant design, suitable for various industrial production environment. The integrated, four-wire non-polar connection mode makes the installation and use extremely simple, and can easily access the user's automated management system. Real-time monitoring of the working conditions of its upstream equipment to achieve early alarm, convenient maintenance of upstream equipment, so as to avoid waste and unnecessary damage to downstream equipment. The application of dust online instrument can play an auxiliary role in the process of energy saving and efficiency improvement implemented by enterprises.
Product characteristics
The main body of the product adopts the integrated structure, the current signal transmission distance is long, and the anti-interference ability is strong.
Set the upper alarm value, output the upper computer alarm when the dust concentration exceeds the standard, and automatically release the alarm when the dust concentration is normal, without manual reset.
The measuring electrode is sprayed with imported material, which has stronger high temperature resistance, corrosion resistance and adhesion resistance.
The main part of the sensor adopts a patented design, and the gas-tight connector strictly prevents the leakage of the measured gas and the impact extrusion of the measuring electrode due to pressure.
Non-polar power supply, using industrial four-wire power supply output, high safety.
Realize the three functions of no open cover wiring, no maintenance and no debugging.
The nitrogen backblowing valve can be added according to the requirements to realize the automatic cleaning function of the induction electrode of the equipment online and ensure the accuracy of the equipment monitoring.
Project name | Argument |
| Measuring accuracy | ±2.5%FS |
| Measuring pressure | ≤2.5MPa |
| Range | 0-10000mg/m³ (large range can be customized) |
| Insert length | L=500mm, L=800mm (standard type), special size can be customized. |
| Output mode | Four-wire, no polarity, no open cover connection |
| Wiring mode | Switching output |
| Supply voltage | DC24V |
| Protection class | IP65/NEMA4 aluminum alloy housing |
| Use | Detection of bag damage, or recovery of powdery materials, monitoring of total product delivery, or monitoring of boiler dust emission concentration of various sizes and fuels. |
| Function | On-line monitoring of dust content in gas-solid two-phase flow/bag leak detection/flow monitoring of powdery materials / |
| Origin | Qingdao |
| Weight | ≈5KG |